LVDS to LVPECL & PECL: Fig. 3, 9, 12.
vice versa also, in different figures
Use Fig. 3 if LVDS source is across a backplane (ie: because source is on a
different board on a separate dc supply, hot swap ability, rcvr doesn't have
Vcmr to match LVDS), or use Fig.9 - dc coupled - if on same board and
using a rcvr w/ compatible Vcmr inputs. The Fig.3 1k/100k pull down/up
aren't needed if rcvr inputs have an equivalent network, like the LVEL17.
Lyke James Civ AFRL/VSSE wrote:
> Is there a simple way to interface between LVDS and PECL?
> jim
>
> **** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu/si-list ****
-- Thanks, John Lipsius Member Technical Staff Cyras Systems, Inc. 46832 Lakeview Blvd. Fremont, CA 94538 510-623-6631