RE: [SI-LIST] : ibis2spice

About this list Date view Thread view Subject view Author view

From: Muranyi, Arpad ([email protected])
Date: Fri Dec 15 2000 - 13:44:37 PST


Regarding the message fragment below, you must be referring to
the C_comp capacitor being connected to node 0 and not to the
appropriate IV curve reference node(s). That has also been
fixed, I believe in H2000.2. You can now split C_comp into
four parts, and each of those are connected to the corresponding
voltage reference nodes.

Arpad Muranyi
==================================================================

-----Original Message-----
From: Ingraham, Andrew [mailto:[email protected]]
Sent: Thursday, December 14, 2000 2:10 PM
To: si-list
Subject: RE: [SI-LIST] : ibis2spice

HSPICE's implementation has a few other quirks, like internal connections to
node 0 which can be a problem sometimes, for which a functionally-equivalent
SPICE subcircuit could come in handy.