Ravi,

If the differential lines carry low amplitude signals, it will be
beneficial to use a guard band around them. However, presence of guard
band will cause a reduction in the characteristic impedance of differential
lines. It will be advisable to use a 2-D field solver to determine the
quantitative effect of impedance change due to guard band.

Regards, Ravinder
PCB Development and Design Department
IBM Corporation - Storage Systems Division
Email: [email protected]
***************************************************************************
Always do right. This will gratify some people and astonish the rest.
.... Mark Twain

Ravi Kiran <[email protected]>@silab.eng.sun.com on 07/26/2000 05:23:39
PM

Please respond to Ravi Kiran <[email protected]>

Sent by: [email protected]

To: [email protected]
cc:
Subject: [SI-LIST] : Guard band for differential signals

Hi,

Is it advisable to provide ground guard band for differential signals?
What will be the effect of guard band for differential signals?

Thanks