RE: [SI-LIST] : or3t125a.ibs

About this list Date view Thread view Subject view Author view

From: Cusanelli, Tony ([email protected])
Date: Mon May 08 2000 - 04:52:36 PDT


Inmyung Song

   The file seems to have a problem with units. The ICX model check is
reporting that there are non-monotonic points in the curve. If you look at
the data you will see that the currents are decreasing and then change
dramatically. The simple assumption is that the units should change from
ma to ua, but I think you need to contact the supplier for more information
about how the model was created. I also noticed that someone commented out
the values around zero for the power clamp. I see the same issue - the
currents are too large.

Regards,
Tony

-----Original Message-----
From: Song In-myung [mailto:[email protected]]
Sent: Sunday, May 07, 2000 5:49 AM
To: PCB Design Mail Group
Subject: [SI-LIST] : or3t125a.ibs

Hello everyone.

I am from south korea and the pcb designer.
Now I am training IS made by mentorgraphics.
During importing this IBIS model into IS, there are 3 parser errors but I
can't fix these.

Please help me.
Other IBIS model checker pass this IBIS model and made non-error except IS.

Thank you for your great help.

    Inmyung Song.

**** To unsubscribe from si-list or si-list-digest: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
si-list archives are accessible at http://www.qsl.net/wb6tpu
****


About this list Date view Thread view Subject view Author view

This archive was generated by hypermail 2b29 : Wed Nov 22 2000 - 10:50:13 PST