RE: [SI-LIST] : or3t125a.ibs

About this list Date view Thread view Subject view Author view

From: Chien, Ruey Wen ([email protected])
Date: Sun May 07 2000 - 20:30:26 PDT


Inmyung:

Your problem is the non-monotonicity of VI curve. IS checks 3 non-
montonicities, sum of clamp curves, sum of clamps and pull-up, sum of
clamps and pull-down.

You may turn off the model checker for non-monotonicity checking.

The attachment includes two scheme file for off and on the modelchecker.

Ruey-Wen Chien
Intel

-----Original Message-----
From: Song In-myung [mailto:[email protected]]
Sent: Sunday, May 07, 2000 8:49 PM
To: PCB Design Mail Group
Subject: [SI-LIST] : or3t125a.ibs

Hello everyone.

I am from south korea and the pcb designer.
Now I am training IS made by mentorgraphics.
During importing this IBIS model into IS, there are 3 parser errors but I
can't fix these.

Please help me.
Other IBIS model checker pass this IBIS model and made non-error except IS.

Thank you for your great help.

    Inmyung Song.





**** To unsubscribe from si-list or si-list-digest: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.