Adding to what D. C. Sessions already wrote....
>Doesn't the 5V spec also have a clamp requirement?
>It is just a clamp to 5V.
No, the "high" clamp is optional in the 5V spec. Only the clamp below
ground is required.
>Just curious about how many preople have seen high side
>ringing problems with 5V tolerant universal buffers in
>a 5V system becuase it drives to 3.3 but the bus clamps at 5V.
Whether the clamp is there or not, ringing can happen that never hits the
clamp.