RE: [SI-LIST] : What speed scope should I consider?

About this list Date view Thread view Subject view Author view

From: Muranyi, Arpad ([email protected])
Date: Fri Nov 12 1999 - 16:47:16 PST


I meant impedance vs. time, or non steady state but varying impedance,
such as the impedance of a buffer turning on/off vs. time.
 
Arpad
==========================================================================
 
-----Original Message-----
From: Ron Miller [mailto:[email protected]]
Sent: Friday, November 12, 1999 3:54 PM
To: [email protected]
Subject: Re: [SI-LIST] : What speed scope should I consider?

Try Tektronix 11801 or a similar sampling scope from HP with the
TDR option.

Ron Miller

"Muranyi, Arpad" wrote:

Does anyone know of any instrument that can measure transient impedance?

Arpad Muranyi
Intel Corporation
========================================================================

Quote from previous correspondence:

"Network analyzers measure steady state impedance, not transient impedance."

**** To unsubscribe from si-list: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list, for more help, put HELP. si-list archives are accessible at
http://www.qsl.net/wb6tpu/si-list <http://www.qsl.net/wb6tpu/si-list> ****

-- 

Ronald B. Miller _\\|//_ Signal Integrity Engineer

(408)487-8017 (' 0-0 ') fax(408)487-8017

==========0000-(_)0000===========

Brocade Communications Systems, 1901 Guadalupe Parkway, San Jose, CA 95131

[email protected], [email protected]

**** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu/si-list ****


About this list Date view Thread view Subject view Author view

This archive was generated by hypermail 2b29 : Tue Feb 29 2000 - 11:39:47 PST