Sincerely,
ed sayre
At 06:53 PM 12/4/97 +0900, you wrote:
>Does anyone help on the effect of EMI suppression owing to the difference
>of copper thickness which is located on the inner layer of multi_layer
>board ?
>(This layer is used for GROUND or POWER plane.)
>
>
>Which is better the thickness become thick or thin ?
>
>And what is the reason why ?
>
>Thanks in advance.
>
>Best Regards.
>-------------------------------------------------------------
>Takashi Yanagimoto
>
>Ricoh Company Ltd.
>Tokyo Japan
>
>Email:[email protected]
>--------------------------------------------------------
>
>
>
>
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~+
| NORTH EAST SYSTEMS ASSOCIATES, INC. |
| ------------------------------------- |
| "High Performance Engineering & Design" |
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~+
| Dr. Ed Sayre e-mail: [email protected] |
| NESA, Inc. http://www.nesa.com/ |
| 636 Great Road Tel +1.508.897-8787 |
| Stow, MA 01775 USA Fax +1.508.897-5359 |
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~+