To add to that comment: wouldn't the increased capacitance of the
PWR/GND distribution network further reduce SSN?
regards
Nirmal
>
>Hi,
>
>Just one comment about splitting a wide line into multiple narrow
>lines with the same total width: the inductance will go down, but
>the capacitance will go up because of all the extra peripheral
>capacitance.
>
>Paul
>
-- _______________________________________________________________________________ Nirmal Jain ANSOFT CORPORATION (412) 261-3200 X29 (W) Four Station Sq., Suite 660 (412) 471-9427(FAX) Pittsburgh, PA 15219 _______________________________________________________________________________You make more friends by becoming interested in other people than by trying to interest other people in yourself. -- Dale Carnegie