Re: [SI-LIST] : FCAL data pattern

David Instone ([email protected])
Wed, 13 Oct 1999 09:49:43 -0400

k28.5 = 0011111010 if the running disparity (RD) is '-' or the inverse
if RD is '+'
k28.7 = 0011111000 if RD '-' or the inverse if RD '+'

Chris Cheng wrote:
>
> sorry for being lazy and not digging the 400 page + spec,
> can anyone send me the data pattern spec for K28.5 and
> K28.7 in the X3.230-1994 standard ?
> thanks in advanced.
> chris
>
> **** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at

-- 
Regards

Dave Instone Test Systems, MP24/22 Xyratex, Langstone Rd., Havant, Hampshire, P09 1SA, UK. Tel +44 (0)1705 486363 ext 3071 or +44 (0)1705 443071 (direct line) Fax +44 (0)1705 499315 http://www.xyratex.com

**** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu/si-list ****