I'm assuming you mean this:

> D. C. Sessions wrote:

> > Actually, for a CMOS point-to-point connection you get surprisingly
> > good results with a single resistor in the center of the trace.

It *only* works for point-to-point connections, so your application
can't use it. For multi-drop busses endpoint shunt termination is
the only reliable high-speed method.

-- 