(Fwd) [SI-LIST] : Re: viewing the output of LARGE hspice transient runs

Pat Zabinski ([email protected])
Fri, 5 Feb 1999 16:07:56 -0600

One possible method is to use the "CSDF=2" option. This will
force the .tr0 file into a "common simulation data format" that
other tools (other than Awaves) can read in. In addition,
the .tr0 file is now ascii, so you can create a script that will
chop the large file into smaller files and look at them
individually.

Not exactly a great solution, but it gets the job done.

Pat Zabinski

>
> Ray Anderson Wrote:
>
> >A quick question to the list, has anyone sucessfully opened
> >a large (> 3GByte) .tr0 data file generated by Hspice with the Avant!
> >Awaves viewer?
>
> >The simulation is the result of a colleague's overnite oscillator
> >startup simulation and seems to have run to completion without errors.
>
> >Relevant comments and/or experiences solicited
>
>
> Not realy an answer, but when I want to simulate
> oscilator startup, I seed the oscilator with a
> small sinusoid of the expect frequency.
>
>
>