[SI-LIST] : Stripline VS. Microstrip losses

About this list Date view Thread view Subject view Author view

From: Pritchard, Jason ([email protected])
Date: Mon Apr 23 2001 - 14:27:34 PDT


If I have 2 transmission lines, 1 embedded in stripline with equal spacing
between the signal conductor and both planes and the other in microstrip.

1) How much does the proximity effect increase the copper losses/skin effect
in microstrip vs. that of stripline?

2) I presume the dielectric losses are less in microstrip. If that is true,
is there a point where it cancels out the negative effects of question 1?

3) Which do you prefer when trying to decrease copper and dielectric losses
and why?

Thanks,