Gary:

Definitely near the chip side. The power/ground sandwich will provide the
maximum initial rate of charge delivery to the IC and the chip capacitors
charge delivery will be limited/slowed by the via inductance from the bottom
layer to the top layer. The IC pin inductance will be a deterrent in both
cases.