Modifications for the Kenwood 
TS-660

08-04-2000 TS-660 Microprocessor 
Latchup
Author: Trio-Kenwood 
Communication, inc.
Service Bulletin no. 856 (25-1-1982)
Microprocessor latchup may occur if the power switch is cycled sevela: times 
in quick succession, if the supply is turned off while the power switch remains 
on, or if the power supply is turned on with the transceiver already on. Symptom 
will be no display, erroneous display, or locked display. Change two components 
on the control unit to prevent further trouble. 
On the control unit X53-1220-00: 
  - Replace R23 680 ohm with a 470 ohm resistor (RD14CB2E471J). 
  
 - Remove and delete C4 47uF 
  
 - Add a 22uF 16V electrolytic (CE04W1C220M) on the foil side on the board 
  between D24, R23 (positive) and ground (negative). 
 
Notes: 
  - This change applies to units before serial number 209xxxx. 
  
 - Installation time for this procedure is ½ hour or less. 
 