Modifications for the Kenwood
TS-660

08-04-2000 TS-660 Microprocessor
Latchup
Author: Trio-Kenwood
Communication, inc.
Service Bulletin no. 856 (25-1-1982)
Microprocessor latchup may occur if the power switch is cycled sevela: times
in quick succession, if the supply is turned off while the power switch remains
on, or if the power supply is turned on with the transceiver already on. Symptom
will be no display, erroneous display, or locked display. Change two components
on the control unit to prevent further trouble.
On the control unit X53-1220-00:
- Replace R23 680 ohm with a 470 ohm resistor (RD14CB2E471J).
- Remove and delete C4 47uF
- Add a 22uF 16V electrolytic (CE04W1C220M) on the foil side on the board
between D24, R23 (positive) and ground (negative).
Notes:
- This change applies to units before serial number 209xxxx.
- Installation time for this procedure is ½ hour or less.
