Ten-Tec Omni VI ! Radio Model for display within Log-EQF --- 01/31/93 --- 1.0 ! Update rate in seconds - 0 is fast, while 10 is slow! ! Acknowledge command, if required 6 ! Bytes received from radio for ECHO or OK block ! Pacing or Initialize command, if required H ! Hexadecimal (H) or String (S) instruction data type F ! Commands sent to radio Forward (F) or Reverse (R) order ! -------------- FREQUENCY READ ------------------------- FEFE04E003FD ! Command to receive operating FREQUENCY from radio 10 ! Number of bytes expected from radio after FREQ command 6 ! Starting byte position for FREQUENCY value 4 ! Number of bytes in FREQUENCY value R ! Frequency decoded in Forward (F) or Reverse (R) order B ! BCD (B) or Weighted Binary (W) ! -------------- MODE READ ------------------------------ FEFE04E004FD ! Command to receive operating MODE from radio 7 ! Number bytes expected from radio after MODE command 6 ! Starting byte position for MODE value 1 ! Number of bytes in MODE value ! Bit mask for MODE value, if required 03 ! Value for CW 00 ! Value for LSB 01 ! Value for USB 05 ! Value for FM 02 ! Value for AM 07 ! Value for FSK ! -------------- FREQUENCY SET -------------------------- FEFE04E00500000000FD ! Command to set the operating FREQUENCY 6 ! Starting byte position for FREQUENCY value 4 ! Number of bytes in FREQUENCY value ! -------------- MODE SET ------------------------------- FEFE04E00600FD ! Command to set the operating MODE 6 ! Starting byte position for MODE value 1 ! Number of bytes in MODE value 03 ! Value for CW 00 ! Value for LSB 01 ! Value for USB 05 ! Value for FM 02 ! Value for AM 07 ! Value for FSK