5 9600 BAUD PARAMETERS ~~~~~~~~~~~~~~~~~~~~ As you'd expect, the parameters we all know and love at 1200 baud don't work very well at 9600 baud. These are what we've found work well at 9600. 5.1 AX.25 PARAMETERS TXDelay between 8 and 15 - set for best throughput RESPtime 100 mS seems to have better results than 0 FRack 8 seconds on a busy channel; but never less than 5 seconds PERSIST 128/users; if it's a pretty clean channel, 64 is nice; if it's busy, guesstimate the average number of users and divide 128 by this number, i.e. 4 users = 128/4 = 32 SLOTTIME 20 MAXFrame If the channel is great, 7; average, 3; rough, 1 RETry 15 CHeck 300 seconds 5.2 TCP/IP PARAMETERS ~~~~~~~~~~~~~~~~~ My 9600 baud interface is called "96"; here are params from my files. par 96 1 8 par 96 2 64 par 96 3 20 par 96 4 2 ax25 maxframe 3 ax25 paclen 256 ax25 pthresh 64 ax25 retry 15 ax25 t1 8000 ax25 t2 1000 ax25 t3 300000 ax25 t4 900000 mode 96 datagram ax25 persist 96 256 5 128 15 60 Some of these parameters are specific to pe1chl NET, so don't get an ulcer if your version barfs on them. 6 HELP If you have a radio you'd like to use for 9600 baud, but don't know where to find the "magic points", send me 2 copies of the schematics - one for me, and one for you (block diagrams are nice but not absolutely required), and a stamped, addressed return mailer. I'll get out my red "test grading" marker and mark the points where you'll find raw RXA and TXA. Some of these mods are tested, and some aren't, but should work fine. These are non-destructive (yup - you can still use it for whatever it was used for before), and are generally a simple matter of tacking 2 caps to easily accessible spots on the PCB, adding the 2 resistors, attaching 2 pieces of mini shielded cable, and bringing the 2 connections out. Yours, _ _ _ __ ' ) ) ) / / ) _/_ / / / o /_ _ / . . __ / o _ / ' (_<_/ <_(/_ (__/ (_/_/ (_<__<_/_)_ Packet: WD6EHR@n6yn.#soca.ca.usa WD6EHR@WD6EHR.ampr.org [44.16.0.21] Internet: WD6EHR.ampr.org!WD6EHR@puffin.UUCP Compu$erve 73240,3523 WD6EHR-3 netrom switch WD6EHR-6 conference bridge WD6EHR-8 mbox/info 145.36- 1200/9600 baud duplex repeater <----> 439.025 - both @9600 baud 7921 Wilkinson Avenue; North Hollywood CA USA 91605-2210 (818) 765-2857