G0ORY IO92KP Leicester England

(* ON TEST *)

ANT: NAiS VIC-100


To learn more about the software which generates this data, please visit K8CU at:

www.realhamradio.com


Power-on time
Days Hrs Mins Secs
           HEWLETT-PACKARD,Z3801A,3542A06309,3543-A. Life count: 7045
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -500 ps relative to GPS
   Holdover                                   HOLD THR 100.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  1.8 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time ____________________________
Tracking: 3        Not Tracking: 3            UTC      21:41:15     26 Jun 2003
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  5  69 230   93   * 7  Acq .                 ANT DLY  25 ns
 14  36 305   42   * 9  Acq .                 Position ________________________
 23  18 262   68   *30  Acq .                 MODE     Hold
                                              
                                              LAT      N  52:37:43.548
                                              LON      W   1:09:09.156
ELEV MASK 10 deg   *attempting to track       HGT               +75.64 m  (MSL)
HEALTH MONITOR ......................................................... [ OK ]
Self Test: OK    Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK