IC-756Pro3/Quadra ALC Overshoot Test

by Adam Farson VA7OJ/AB4OJ

Fig.1: Test screenshot.
Fig.1: Test screenshot.

On 27 August 2007, I ran an ALC overshoot test on my IC-756Pro3/Yaesu Quadra station as follows:

Initial setup:

Frequency: 14140 kHz. Quadra Po = 1kW. Required drive power 70W.

Test configuration:

  1. Pro3 ANT1 ⇒ Bird 4273-025 line sampler ⇒ Bird 43 power meter ⇒ Quadra Input 1.

  2. Sampling port of line sampler connected to Tektronix 455 oscilloscope Channel 1, terminated in 50Ω.

  3. Scope set to 0.2V/div vertical, 0.1 sec/div horizontal.

Test procedure:

  1. Key exciter in USB mode, with Mic Gain fully CCW: no RF output; no spike.

  2. Key exciter in RTTY mode: Drive drops off approx. 6% in first 100 mS, then settles.

Fig.1 illustrates what is happening. ALC settling time is approx. 100 mS, but there is no damaging overshoot.