GU74B ----- 2B-1PA: Ua = 2.2 kV Ug2 = 300 V Ug1 = -55 ... -60 V (adjust Ia0=50mA) Ia0 = 50 mA Ig2 = 50 mA max. Ig1 = 15 mA max. Uh = 12.6 V Ih = 3.3 - 3.9 A 2m: --- Pdrv = 32 W Ctg2 = 87 pF (10-150 pF trimmer cap.) Ccg2 = 15 pF (3-30 pF trimmer cap.) Cta2 = 18 pF (3-30 pF variable cap. for High Voltage!) Cca2 = 10.5 pF (3-30 pF variable cap. for High Voltage!) Lg2: I.D. = 11 mm len. = 12mm n = 4 turns dw = 1.5 mm Cul La2: I.D. = 50 mm len. = 5 mm n = 1 turns dw = 5 mm 6m: --- Pdrv = 5W Ctg6 = 300 pF (150-500 pF trimmer cap.) Ccg6 = 95 pF (30-150 pF trimmer cap.) Cta6 = 24.5 pF (10-50 pF variable cap. for High Voltage!) Cca6 = 14.5 pF (5-30 pF variable cap. for High Voltage!) Lg6: I.D. = 13 mm len. = 16mm n = 6 turns dw = 1.5 mm Cul La6: I.D. = 40 mm len. = 35 mm n = 4 turns (tap at 2 turns) dw = 5 mm 73 de YU1AW