TubePad 6.0 Tube Chart

Quick Reference Data

Name: 31
Use:
Glass type used in output stage of battery-operated receivers.
Notes: Requires a 4- pin socket.


31
Power Amplifier
Data Source= Collins Handbook, 1940 ed.
Heater or Filament Voltage= 2.0 volts
Heater or Filament Current= 0.13 amperes
EIA Base= 4D
Substitutes= None



Capacitances and Design Maximum Values
Heater or Filament Voltage . . . 2.0 volts
Heater or Filament Current . . . 0.13 amperes
C/in. . . . . . . . . . . .      3.7 pf
C/out . . . . . . . . . . .      2.2 pf
C/gp. . . . . . . . . . . .      5.7 pf
Maximum Plate Voltage . . .      180 volts


Typical Operation as a Receiving Tube
                   
Description          Ep    Eg   Es  Is  Ip    Rp    TC   AF    Zl   PO
========================================================================
Class A Amplifier   180  -30    -   -  12.3  3600  1050  3.8  5700 0.375
Class A Amplifier   135  -22.5  -   -   8.0  4100   925  3.8  7000 0.185