From: ªL´Â·× ([email protected])
Date: Tue Jan 16 2001 - 23:43:30 PST
Scott,
Is it necessary to be 50 ohms?
Shall rfixture be the same as the resistor in test load, used for generating
AC timing spec?
Best Regards,
John Lin
Senior SI Engineer, Server Team, ARD4
Quanta Computer Inc.,Taiwan, R.O.C.
Email: [email protected]
Tel: 886+3+3979000 ext. 5183
-----Original Message-----
From: Scott McMorrow [mailto:[email protected]]
Sent: Wednesday, January 17, 2001 2:36 PM
To: Doug Hopperstad
Cc: [email protected]
Subject: Re: [SI-LIST] : RE: IBIS model question
Doug,
The model is incorrectly extracted. The rfixture should have
been 50 ohms.
scott
Doug Hopperstad wrote:
> I have a question regarding the IBIS model format. Within the model there
> R_Fixture. I understand that the R_fixture was used to create the rise and
> fall time charts. My question is the value of the resistor. Is there a
> relationship of the resistor to a load resistor that would be used in the
> lab? The information below came from a SSTL-2 output model.
>
> Vref = 1.250V
> Rref = 0.125k
> Cref = 10pF
> Vmeas = 1.250V
>
> [Rising Waveform]
> R_fixture = 0.125k
> V_fixture = 1.250
> V_fixture_min = 1.250
> V_fixture_max = 1.250
>
> R_load = 0.125k
>
> How come the resistor value does not reflect a more typical 50 ohm
> application?
>
> Doug Hopperstad
>
> **** To unsubscribe from si-list or si-list-digest: send e-mail to
> [email protected]. In the BODY of message put: UNSUBSCRIBE
> si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
> si-list archives are accessible at http://www.qsl.net/wb6tpu
> ****
-- Scott McMorrow Principal Engineer SiQual, Signal Quality Engineering 18735 SW Boones Ferry Road Tualatin, OR 97062-3090 (503) 885-1231 http://www.siqual.com**** To unsubscribe from si-list or si-list-digest: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu ****
**** To unsubscribe from si-list or si-list-digest: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu ****
This archive was generated by hypermail 2b29 : Tue May 08 2001 - 14:30:38 PDT