I need to run the trace through the a pin field. The room between pins is 2mm
and because of the dielectric thickness constraint I can only run a single 12
mil wide line through the pin field. If I use a single 35 ohm line, the trace
width is too large to fit through the pin field.
Thanks,
-- Sal
Michael Nudelman <[email protected]> on 10/27/2000 03:10:31 PM
Sent by: Michael Nudelman <[email protected]>
To: Salvador Aguinaga/MW/US/3Com
cc: [email protected]
Subject: Re: [SI-LIST] : Parallel single-ended traces routed to achieve 35 Ohm
controlledimpedance
E-r-r-r....Any particular reason for doing this exercize?
[email protected] wrote:
> Has any one tried to achieve controlled impedance for a single-ended trace by
> running two traces in parallel?
>
> ==================== GND PLANE
> DIELECTRIC THICKNESS T1
> +-----+
> |/////| SINGLE TRACE 70 OHMS
> +-----+
>
> DIELECTRIC THICKNESS T2 (T2>T1)
>
> ==================== GND PLANE
>
> +-----+
> |/////| SINGLE TRACE 70 OHMS
> +-----+
>
> ==================== GND PLANE
>
> Using this trace geometry, if each trace is 70 Ohms relative to its reference
> planes, and I tie them together at the ends, will this yield 35 Ohms or
> something a little less than half Zo of each trace?
>
> Thanks,
> -- §al Aguinaga Jr.
> -- 3Com - Carrier Business Networks
> -- Mt. Prospect, IL
>
> **** To unsubscribe from si-list or si-list-digest: send e-mail to
> [email protected]. In the BODY of message put: UNSUBSCRIBE
> si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
> si-list archives are accessible at http://www.qsl.net/wb6tpu
> ****
**** To unsubscribe from si-list or si-list-digest: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
si-list archives are accessible at http://www.qsl.net/wb6tpu
****
This archive was generated by hypermail 2b29 : Tue May 08 2001 - 14:29:52 PDT