From: Larry Miller (ldmiller@nortelnetworks.com)
Date: Fri Sep 15 2000 - 13:44:00 PDT
Are you talking about 1) two striplines on opposite sides of a sheet of
ground plane?
Or 2) do you mean two adjacent striplines on the same side of the ground
plane?
It looks like you mean 1)
Larry Miller
> -----Original Message-----
> From: Sean Murray [SMTP:seandm@mmspec.com]
> Sent: Friday, September 15, 2000 12:10 PM
> To: si-list@silab.eng.sun.com
> Subject: [SI-LIST] : trace to trace coupling
>
> Does anyone know the formula in order to calculate the coupling percentage
> between two signals seperated by a solid ground plane? At what
> frequency/edge rate does one have to start thinking about staggering their
> traces so that they do not get coupling between two stripline layers..
>
> Regards,
> Sean Murray
> General Manager
>
> M&M Specialties Inc.
> 1236 W. Southern Ave. #106
> Tempe, AZ. 85282-4518
> Phone: (480) 858-0393 x105
> Cell: (602) 684-7859
> Fax: (480) 858-1882
> Email: seandm@mmspec.com
> WWW.mmspec.com
>
>