RE: [SI-LIST] : trace to trace coupling

About this list Date view Thread view Subject view Author view

From: Larry Miller ([email protected])
Date: Fri Sep 15 2000 - 13:44:00 PDT


Are you talking about 1) two striplines on opposite sides of a sheet of
ground plane?

Or 2) do you mean two adjacent striplines on the same side of the ground
plane?

It looks like you mean 1)

Larry Miller

> -----Original Message-----
> From: Sean Murray [SMTP:[email protected]]
> Sent: Friday, September 15, 2000 12:10 PM
> To: [email protected]
> Subject: [SI-LIST] : trace to trace coupling
>
> Does anyone know the formula in order to calculate the coupling percentage
> between two signals seperated by a solid ground plane? At what
> frequency/edge rate does one have to start thinking about staggering their
> traces so that they do not get coupling between two stripline layers..
>
> Regards,
> Sean Murray
> General Manager
>
> M&M Specialties Inc.
> 1236 W. Southern Ave. #106
> Tempe, AZ. 85282-4518
> Phone: (480) 858-0393 x105
> Cell: (602) 684-7859
> Fax: (480) 858-1882
> Email: [email protected]
> WWW.mmspec.com
>
>
> **** To unsubscribe from si-list or si-list-digest: send e-mail to
> [email protected]. In the BODY of message put: UNSUBSCRIBE
> si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
> si-list archives are accessible at http://www.qsl.net/wb6tpu
> ****
>

**** To unsubscribe from si-list or si-list-digest: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP.
si-list archives are accessible at http://www.qsl.net/wb6tpu
****


About this list Date view Thread view Subject view Author view

This archive was generated by hypermail 2b29 : Tue May 08 2001 - 14:29:30 PDT