FWD+: Re: [SI-LIST] : Trace impedance

[email protected]
Wed, 26 Aug 98 17:00:26 EDT

I agree with Fabrizio. Get a good field solver. I have found that if I use our
internal field solver I can accurately predict impedance, delay and crosstalk.
Moreover if I feed the results into HSPICE (using wline models) I can get near
perfect match when I overlaying bench waveforms and HSPICE simulated waveforms.
I recommend;

1. Measure impedance, delay, and response to some input stimulus using a
high bandwidth scope and TDR.
2. Accurately measure actual physical geometries of traces from cross-sections.
3. Create spice model (or RLGC file) from field solver (if possible).
4. Compare Measured results to simulated results

One can obtain excellent correlation, as good as test equipment measurement
accuracy provided your have a 'good' field solver and accurate input
information. just my $.02.
regards, bob

Robert J. Haller
Principal Hardware Engineer
Compaq Computer Corporation (formerly Digital)
129 Parker St. PK03-01/N97
Maynard Ma. 01754-32198

(978) 493-4112
[email protected]

-----------------Forwarded item dated 20-AUG-1998 13:49:10.16-----------------

From: US8RMC::"fabrizio=zanella%eng%[email protected]"
To: "casperdd" <[email protected]>, <[email protected]>
CC: "[email protected]" <[email protected]>
Subj: Re: [SI-LIST] : Trace impedance

Gentlemen, formulae for calculating impedances of stripline/microstrip
traces are only somewhat accurate for certain geometries. The formulae
were developed many years ago, when line widths were .010"+, dielectric
thicknesses differed from today's designs, and most designs used 50 ohm
transmission lines. For high impedance tlines, (80+ ohms), the accuracy of
the formulae gets terrible.
If you want to match your TDR measured impedances to calculations, you need
to use a field solver tool. There are many good tools available that use
boundary element or finite element analysis. Try Apsim's 'RLGC' tool, or
Ansoft's Maxwell EZ2D.

Regards,
Fabrizio Zanella
EMC Corporation
[email protected]
-------------
Original Text
From: "Bill Dempsey" <[email protected]>, on 8/20/98 1:05 PM:
To: smtp@Eng@EMCHOP1["casperdd" <[email protected]>]
Cc: smtp@Eng@EMCHOP1["[email protected]"
<[email protected]>]

casperdd wrote:

> Hi
>
> I was hoping that someone might be able to shed a little light on a
> problem that I have encountered regarding the impedance of stripline,
> and microstrip PCB tracks.
> I require a formula that is capable of predicting the impedance's of
> stripline, and microstrip tracks. I have already found several from
> different source, but none of them seem to agree with each other, my
> TDR
> results, or the TDR results from "MECL system design handbook" by
> Motorola. All the formulas that I have come across claim to have an
> accuracy to within about 5%, but as far as I can tell the discrepancy
> can reach up to 20%, depending on the dimensions involved.
> The region of interest to me is:
>
> Track width = 10 mils
> Track thickness = 1.37 mils
> Ground plane/Track separation (dielectric height) = 8 mils
> Relative permittivity = 4.7
> TDR edge rise time = 28ps
>
> The most alarming problem that I have encountered is the natural
> logarithm that most formula seem to have, this then returns a negative
>
> number when its argument is smaller than one, even though most formula
>
> claim to still be accurate at this limit.
>
> I would appreciate it if anyone could show me where I have been going
> wrong, or point me in the direction of an accurate formula.

Plenty of research has gone into most of the formulas. Assuming a
"fixed" value of er= 4.7 somewhat troubles me as this value is not a
constant over frequency. er = 4.7 *seems* high to me. I suspect you'll
be able to empirically determine the er at the frequency of interest if
you build some test boards. Most good board shops know how their
material acts at these higher frequencies and back their numbers up with
real-world measurements. Check around and see what they think your
materials' er is in the gigahertz region.

Also check with IPC -- they have a technical paper IPC-TP-949 that
covers measuring impedance of stripline/microstrip traces. It's written
for the layman so it's easy to read.

Hope this helps,
Bill Dempsey

>
>
> Many Thanks
>
> Dominic Casperson
>
> **** To unsubscribe from si-list: send e-mail to
> [email protected]. In the BODY of message put: UNSUBSCRIBE
> si-list, for more help, put HELP. si-list archives are accessible at

**** To unsubscribe from si-list: send e-mail to
[email protected]. In the BODY of message put: UNSUBSCRIBE
si-list, for more help, put HELP. si-list archives are accessible at
http://www.qsl.net/wb6tpu/si-list ****

**** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu/si-list ****

% ====== Internet headers and postmarks ======
% Received: from mail13.digital.com by us8rmc.bb.dec.com (5.65/rmc-17Jan97) id AA01715; Thu, 20 Aug 98 13:44:46 -0400
% Received: from mercury.Sun.COM (mercury.Sun.COM [192.9.25.1]) by mail13.digital.com (8.8.8/8.8.8/WV1.0g) with SMTP id NAA14786 for <[email protected]>; Thu, 20 Aug 1998 13:44:45 -0400 (EDT)
% Received: from Eng.Sun.COM (engmail4 [129.144.134.6]) by mercury.Sun.COM (SMI-8.6/mail.byaddr) with SMTP id KAA17662; Thu, 20 Aug 1998 10:20:20 -0700
% Received: from silab.eng.sun.com (silab.Eng.Sun.COM [129.146.121.121]) by Eng.Sun.COM (SMI-8.6/SMI-5.3) with SMTP id KAA00560; Thu, 20 Aug 1998 10:20:16 -0700
% Received: by silab.eng.sun.com (SMI-8.6/SMI-SVR4) id JAA21264; Thu, 20 Aug 1998 09:34:56 -0700
% Errors-To: [email protected]
% Received: from Eng.Sun.COM by silab.eng.sun.com (SMI-8.6/SMI-SVR4) id JAA21255; Thu, 20 Aug 1998 09:34:49 -0700
% Received: from earth.sun.com (earth.EBay.Sun.COM [129.150.69.3]) by Eng.Sun.COM (SMI-8.6/SMI-5.3) with SMTP id JAA19501; Thu, 20 Aug 1998 09:33:01 -0700
% Received: from emcmail.lss.emc.com (emcmail.lss.emc.com [168.159.48.78]) by earth.sun.com (8.9.1/8.9.1) with ESMTP id JAA11855; Thu, 20 Aug 1998 09:32:58 -0700 (PDT)
% Received: from fishbowl02.emc.com (fishbowl02.lss.emc.com [168.159.48.62]) by emcmail.lss.emc.com (8.8.8/8.7.3) with SMTP id MAA00544; Thu, 20 Aug 1998 12:32:12 -0400 (EDT)
% Received: by fishbowl02.emc.com with VINES-ISMTP; Thu, 20 Aug 98 12:32:42 -0400
% Date: Thu, 20 Aug 98 12:25:35 -0400
% Message-Id: <[email protected]>
% X-Priority: 3 (Normal)
% To: "casperdd" <[email protected]>, <[email protected]>
% Cc: "[email protected]" <[email protected]>
% From: "fabrizio zanella" <fabrizio=zanella%eng%[email protected]>
% Reply-To: <fabrizio=zanella%eng%[email protected]>
% Subject: Re: [SI-LIST] : Trace impedance
% X-Incognito-Sn: 1467
% X-Incognito-Version: 4.11.23
% Mime-Version: 1.0
% Content-Type: text/plain; charset=us-ascii
% Sender: [email protected]
% Precedence: bulk

**** To unsubscribe from si-list: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu/si-list ****