Re: [SI-LIST] : Q: HSPICE w-elements' RLCGs - conversion coefficients

Laurence Michaels ([email protected])
Wed, 7 Apr 1999 15:46:17 -0400

Based on experience, XFX seems to give reasonable
results, given reasonable input.

However, the 3D tool, XFX3D is flaky and can give
impossible or unlikely results, such as 0 (self)
inductance for a round connector pin, which was
part of a larger connector structure. That's assuming
it completes the simulation prior to crashing...

Has anyone in- or out-side of Viewlogic experienced
getting good results from XFX3D?

Regards,
-- Laurence