From: Scott McMorrow ([email protected])
Date: Thu Apr 12 2001 - 10:27:39 PDT
Bill Owsley wrote:
> The purpose of the end result may have an effect on the requirement for
> matched length.
> For SI, +/- 5% may be close enough for a decent eye pattern.
> For EMI, that may still be an emission problem.
> ps. Can you get your simulator to show the effects on the sum of the diff
> signals for mis-matched pairs ?
> - Bill
+/- 5% of the edge transition time, is still significantly less than the
launch skew of a typical differential driver due to output imbalance,
package skew due to package routing asymmetry and connector skew.
-- Scott McMorrow Principal Engineer SiQual, Signal Quality Engineering 18735 SW Boones Ferry Road Tualatin, OR 97062-3090 (503) 885-1231 http://www.siqual.com**** To unsubscribe from si-list or si-list-digest: send e-mail to [email protected]. In the BODY of message put: UNSUBSCRIBE si-list or UNSUBSCRIBE si-list-digest, for more help, put HELP. si-list archives are accessible at http://www.qsl.net/wb6tpu ****