New test With ISOTEMP ocxo134-10



Return to Home Page
www.qsl.net/ve2ulu


To learn more about the software which generates this data, please visit K8CU at:

www.realhamradio.com


Power-on time
Days Hrs Mins Secs
           HEWLETT-PACKARD,Z3801A,3542A04047,3543-A. Life count: 12205
------------------------------- Receiver Status -------------------------------
 
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -34.3 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  20.0 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time ____________________________
Tracking: 2        Not Tracking: 6            LOCAL    21:20:20     11 Jul 2005
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  8  42 306   19   * 3  42  57                ANT DLY  0 ns
 27  70 267   28   *11  24 165                Position ________________________
                   *13  Acq .                 MODE     Hold
                    15  13  37                
                   *19  Acq .                 LAT      N  45:37:28.726
                    28  16 279                LON      W  72:57:22.801
ELEV MASK 10 deg   *attempting to track       HGT               +47.27 m  (MSL)
HEALTH MONITOR ......................................................... [ OK ]
Self Test: OK    Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK