US Army Signal Corps Telegraph, Teletypewriter equipment |
Telegraph equipment | Carrier telegraph equipment | Teletypewriter equipment | Teletypewriter Sets | Test Equipment |
BD-100 BE-77 BE-77-A (or B) TG-30 TG-31 TG-5-A TG-5-B |
CF-2-A CF-2-B CF-6 TH-1/TCC-1 |
Teletype... TG-7 TG-37 TG-26 TG-27 TG-11 TG-23 TG-25 |
TC-3 TC-16 TC-17 TC-18 TC-19 TC-22 EE-97 EE-97-A EE-98 EE-98-A EE-102 |
I-193 TS-2 DXD-1 DXD-4 Teletype tuning fork |
Telegraph equipment
BE-77 Line unit To connect neutral circuit to a teletypewriter. Include line relay, line current rheostat and meter. Line relay is adjusted to compensate for bias of incoming line signals. Bias meter I-97 used in making adjustment. Part of Teletypewriter Sets EE-97 and EE-98. |
TG-5-A Telegraph set Manual telegraph set consisting of telegraph key, line relay, oscillator (howler) and telephone headset. Is equipped with a "call" bell. When headset is connected, the oscillator provides a tone in the headphone receiver of about 1000cycles which is under control of line relay. Line relay operates on about 1,5mA and has air-cap and spring-tension adjustment. |
foto |
TG-5-B Telegraph set Same as telegraph set TG-5-A except box is steel instead of aluminium and line relay is more sensitive (0,2mA minimum operating current). Line relay has spring tension adjustment only. |
Carrier telegraph equipment
CF-2-B Telegraph terminal Voice frequency carrier telegraph terminal with four circuits in one bay and essentials the electrical equivalent of Telegraph Terminal CF-2-A. Part of telegraph Terminal TC-22 |
CF-6
Telegraph terminal Voice frequency carrier telegraph terminal containing two circuits for use primarily in combination with Telegraph Terminals CF-2 to provide Channels 5 & 6. The DC loop circuits are like those is Telegraph Terminal CF-2-B. When used with CF-2 equipment, frequency range is 340-2400 cycles. |
TH-1/TCC-1
Telegraph terminal "Speech-Plus Duplex" (D + DX) equipment. Derives one carrier telegraph circuit from a telephone circuit while retaining the voice circuit. Separation of speech and telegraph by hand elimination filters which block out about 1500 to 2000 cycles for telegraph use. Frequency band passed by filters centered at 1680 cycles for one direction of transmission and 1860 cycles for the other direction. DC loops are neutral, half and full-duplex, polarential or two-path polar. Ringing may be voice frequency, 20 cycles or DC. |
Teletypewriter equipment
Teletype |
Teletype model 14 KTR
Key Typing Perforator |
Teletype model 14
Receiving only |
TG-7 special Teletype model 15 RO Page Printer Receiving only |
TG-7-A (or B) Teletype Model 15 KSR Page printer Teletypewriter Page-receiving and keyboard-sending teletypewriter. "Standard" communication keyboard and type-bar arrangement. Pulling magnet selector and no line relay. Series AC governed motor operating on 25, 40 (TG-7-B only) 50 and 60 cycles 115VAC and 115VDC. Motor controlled by switch or automatic built-in control. Motor speed adjusted for 368 or 404 o.p.m. by use of proper tuning fork. The TG-7-B is the same as TG-7-A except that certain minor features not required is tactical services have been omitted. Part of Teletypewriter Sets EE-97, EE-97-A, EE-98, EE-98-A and Telegraph Central Office Set TC-3. |
TG-7 Teletype model 19 TT-7 / TT-8 |
TG-37-B Teletypewriter Same as TG-7-B except equipped with keyboard and type-bar symbols for communication and for sending and receiving of "weather" information. Part of Teletypewriter set EE-102 |
TG-26
Reperforator transmitter Perforates and types message on the tape from keyboard locally or from line signals and send signals from tape run thru transmitter. Typing perforator with keyboard and transmitter distributor mounted on a common wood base which is also the base of the carrying case. Reperforator equipped with "standard" communication keyboard and type-bar symbols. A jack box mounted on the base provides a means of making connections to 60mA neutral circuits. Reperforator supplied with pulling magnet and no line relay. Motors are series AC governed type adjustable for 368 or 404 o.p.m. Motor switch control. Part of Perforator Teletypewriter Set TC-16. |
TG-27 Reperforator transmitter Same as Reperforator Transmitter TG-26 except equipped with reperforator with keyboard and type-bar symbols for communication and for the sending and receiving weather information. Part of Reperforator Teletypewriter TC-17. |
TG-11 Perforator set For perforating tape locally only communications keyboard. Mounted on a metal table which also mounts rectifier to supply DC for perforator solenoid. |
TG-23 Perforator transmitter set Perforates tape locally only and tape is run thru transmitter which sends message. Uses same perforator as Perforator Set TG-11. Both units are mounted on a metal table which also mounts rectifier for operating solenoid of perforator. Series AC governed motor used in transmitter-distributor. This equipment is commercial, "substitute standard". Stop gap for TG-26 |
TG-25 Perforator transmitter set Reperforates tape (without typing) from incoming line signals only. Tape is run thru transmitter which sends message. Equipments mounted in a metal table which also mounts rectifier to provide DC from local circuits. Both units equipped with series AC governed motor with switch control. This equipment is commercial, "substitute standard". Stop gap for TG-26. |
Teletypewriter Sets
TC-3 Telegraph Central Office Set Major
components: |
TC-16 Perforator teletypewriter set Major components: |
TC-17 Perforator teletypewriter set Major components: |
TC-18 Repeater set (terminal) Major components: |
TC-19
Repeater set (intermediate) Major components: |
TC-22
Telegraph terminal set (carrier) Major
components: |
EE-97 Teletypewriter set Major components: |
EE-97-A Teletypewriter set Major components: |
EE-98
Teletypewriter set |
EE-98-A Teletypewriter
set |
EE-102
Teletypewriter set |
Test Equipment
I-193-A Test set Polar relay test set. For testing and adjusting W.E.Co. telegraph polar relays 255A, D-163119A and D-164618. Includes special adjusting tools for these relays. Test set also provides source of 10 or 20 cycles “open-and-closed” signals for lining up the X-61822 carrier telegraph system. Cords supplied for connecting to DC power source, or to rectifier such as RA-37 or RA-87. Power required, 10 watts, 115-130 VDC. |
foto |
Teletype Corp. No DXD-1 Signal distortion test set for use largely in maintenance depots and repair shops. Test signals transmitted from set may be distorted from 0 to 100%. Signals measured by means of a strobosope containing a small neon lamp. Transmitted signals are test message, R and Y, A |
Teletype Corp. No DXD-4 Same as Teat Set DXD-1 except arranged to send “blank” T, O, M, V or “letters” signals in addition to the test message, R and Y signals. Supplied with all required cords. Motor unit and gears are ordered separately. |
Teletype Corp. 103628 Tuning Fork, 87.6 VPS tuning fork for use in adjusting speed of teletypewriter motor to American Standard of 368 OPMI. |
Teletype Corp. 104984 Tuning Fork, 96.19 VPS tuning fork for use in adjusting speed f teletypewriter motor to British Standard of 404 OPM. |