K2 Typical RX Performance Numbers
4/23/99
Here are K2 receive performance numbers and several ARRL rig test
results for comparison. We followed the ARRL Test Procedures Manual,
and our lab test setup was correlated with the ARRL test results by
testing several commercial rigs (TS-50, TS950-SD) on the same setup
and comparing the results to the ARRL numbers.
These are preliminary results and may vary a few DB from rig to
rig. These numbers are for 14Mhz operation, 500Hz CW filter, AGC off,
High Ip mode.
RIG |
MDS(dbm) |
IMDDR3(db) |
Ip3(dbm) |
Ip2(dbm) |
BDR(db) |
K2 |
-136/-132 |
96/97 |
+5/+10.7 |
+70/+72 |
125/133 |
Ten-Tec Scout |
-125 |
87 |
+5.5 |
not meas. |
119 |
Ten-Tec Omni6+ |
-133 |
97 |
+12 |
+58 |
123 (nl) |
FT1000MP |
-135/-128 |
94/97 |
+5/+15 |
+88/+86 |
137/142 |
TS-50 |
-139/-132 |
88/90 |
-7/+3 |
not meas. |
109/113 |
SGC-2020 |
-130 |
88 |
+15.5 |
+32 |
110 (nl) |
XX/YY = preamp-on/preamp-off results
nl = test was noise limited (noise floor rose
1db before 1db of blocking desense occurred)
MDS = Minimum Discernible Signal (3db
increase above noise floor)
IMDDR3 = 2 tone (20 kHz spacing) 3rd order
Dynamic Range
Ip3 = 2 tone (20 kHz spacing) 3rd order
Intercept Point
Ip2 = 2 tone (8.020MHz, 6.000MHz) 2rd order
Intercept Point
BDR = Blocking Dynamic Range (20 kHz spacing)
ARRL Results are from QST rig reviews (Scout,
12/93; Omni6+, 11/97; FT1000MP, 4/96; TS-50, 9/93; SGC-2020, 10/98)
Return to: QRP |