K2 Errata and Measurements |
|
|
|
To Bird dummy load @
13.8v (K2)/13.98 (Fluke after D10) from p.s. |
|
Z of dummy loads |
Power Out |
Current Draw |
V drop |
|
per Autek RF-1 |
K2 |
|
Tabor's |
|
|
|
Fluke 87 |
f (MHz) |
My 9 watt |
Tabor's Bird |
set @ |
K2 |
Telewave |
K2 |
Fluke 87 |
K2 |
(after D10) |
3.75 |
50 |
52 |
4.5 |
4.6 |
3.8 |
1.60 |
1.50 |
0.7 |
0.58 |
|
|
|
5.0 |
|
|
1.65 |
1.60 |
|
|
|
|
|
10.0 |
10.2 |
8.0 |
2.20 |
2.15 |
1~1.1 |
0.90 |
7.10 |
51 |
52 |
4.5 |
4.8 |
4.2 |
1.45 |
1.45 |
0.7 |
0.60 |
|
|
|
5.0 |
|
|
1.65 |
1.55 |
|
|
|
|
|
10.0 |
10.4 |
9.0 |
2.25 |
2.20 |
1~1.1 |
0.94 |
10.10 |
52 |
52 |
4.5 |
4.8 |
4.8 |
1.65 |
1.60 |
0.7 |
0.60 |
|
|
|
5.0 |
|
|
1.70 |
1.60 |
|
|
|
|
|
10.0 |
9.7 |
9.0 |
2.30 |
2.25 |
1.1 |
0.92 |
14.10 |
53 |
52 |
4.5 |
4.8 |
4.8 |
1.60 |
1.60 |
0.7 |
0.66 |
|
|
|
5.0 |
|
|
1.70 |
1.60 |
|
|
|
|
|
10.0 |
9.8 |
9.8 |
2.45 |
2.35 |
1.2 |
1.02 |
18.10 |
54 |
52 |
4.5 |
4.3 |
4.3 |
1.60 |
1.70 |
0.8 |
0.70 |
|
|
|
5.0 |
|
|
1.85 |
1.75 |
|
|
|
|
|
10.0 |
10.2 |
10.2 |
2.70 |
2.60 |
1.3 |
1.14 |
21.10 |
55 |
52 |
4.5 |
4.4 |
4.6 |
1.75 |
1.65 |
0.7 |
0.66 |
|
|
|
5.0 |
|
|
1.80 |
1.70 |
|
|
|
|
|
10.0 |
10.0 |
10.0 |
2.90 |
2.75 |
1.3 |
1.10 |
24.90 |
57 |
54 |
4.5 |
4.4 |
4.8 |
1.90 |
1.75 |
0.8 |
0.70 |
|
|
|
5.0 |
|
|
2.00 |
1.85 |
|
|
|
|
|
10.0 |
10.2 |
10.2 |
2.80 |
2.65 |
1.2 |
1.06 |
28.20 |
58 |
52 |
4.5 |
4.8 |
4.9 |
1.80 |
1.70 |
0.8 |
0.70 |
|
|
|
5.0 |
|
|
1.90 |
1.80 |
|
|
|
|
|
10.0 |
10.0 |
10.2 |
2.75 |
2.60 |
1.2 |
1.06 |
|
|
|
|
|
|
|
|
|
|
Notes: |
1) Power measurements taken
at 4.5 watts to allow 3/4 scale deflection of analog Telewave meter. |
|
2) Current measurements rounded
to 5 mA and averaged where multiple measurements available. |
|
3) Receive current during
TX measurements was 120 mA by K2 display, 127 mA by Fluke 87. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Receive current measurements |
|
|
|
|
|
Format: K2 display value
/ Fluke 87 value; mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LCD |
S-meter |
OPT |
|
|
|
|
|
|
Dot |
Bar |
Off |
|
|
|
|
|
|
Day |
140/142 |
------- |
120/124 |
BATT |
|
|
|
|
|
|
~190/191 |
360/327 |
160/173 |
PERF |
|
|
|
|
|
Night |
160/162 |
------- |
160/155 |
BATT |
|
|
|
|
|
|
220/212 |
280/263 |
~210/205 |
PERF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
1) Audio @ min, Preamp off
(adds 11 mA per Fluke). |
|
|
|
|
|
2) ~190 & ~210 values
are average as K2 fluctuates. |
|
|
|
|
|
3) Dot: 1 segment lit; Bar:
all segments lit. |