S-Meter Measurement

What is my S-Meter telling me?

I've often read how inaccurate S-meters are on most modern HF transceivers. I took the opportunity to test some Icom HF rigs, a 746Pro, 735, 706 and a 756ProII. Below is a table showing the S-meter value, what the levels should be in both microvolts and dBm, and the measured value for each radio. Turns out the 735 and 756ProII tracks the S-meter standard above S-7 pretty closely, but other than that they're all over the map!

<>Check out W7GT's similar review of the Yaesu FT-1000 S-Meter:   Web or Archive


S-Meter Measurements
S-Meter Standard  IC-746Pro
IC-735  IC-706 756ProII
Value  uV dBm  uV dBm Delta  uV dBm Delta  uV dBm Delta uV
dBm
Delta
MDS*  - -  .062 -131 -  .06 -131 -  .07 -130 - .097
-130
-
S1  .2236 -120  5.49 -92 -28  3.20 -97 -23  2.19 -101 -19 2.82
-98
-22
S3  .8902 -108  11.0 -86 -22  6.10 -91 -17  2.48 -99 -9 5.07
-92.9
-15.1
S5  3.544 -96  25.4 -79 -17  12.2 -85 -11  3.35 -96 0 9.12
-87.8
-8.2
S7  14.11 -84  54.3 -72 -12  27.0 -78 -6  11.4 -86 +2 19.1
-81.4
-2.6
S9  56.18 -72  108 -66 -6  76.0 -69 -3  43.6 -74 +2 54.1
-72.2
-.2
S9+10  177.6 -62  495 -53 -9  240 -59 -3  76.7 -69 +6 155
-63.2
+1.2
S9+20  561.8 -52  1.60mV -41 -11  912 -47 -5  133 -64 +12 549
-52.2
+.2
S9+30  1.776mV -42  4.42mV -34 -8  1.95mV -41 -1  227 -60 +18 1.55mV
-43.2
+1.2
S9+40  5.619mV -32  11.4mV -26 -6  4.79mV -33 +1  398 -55 +23 5.69mV
-31.9
-.1
S9+50  17.76mV -22  28.8mV -18 -4  13.8mV -25 +3  776 -49 +27 17.0mV
-22.4
+.4
S9+60  56.18mV -12  66.8mV -10 -2  49.0mV -13 +1  2.04 -39 +27 53.7mV
-12.4
+.4

*MDS- Minimum Discernable Signal
Tests done using my Rohde and Swartz model SMS 2 synthesized signal generator, F=14.200MHz.
Preamps and attenuators not engaged.  Mode=SSB, max bandwidth selected.