Capabilities

 

Gamma spectroscopy- Berkeley SAM-935 w/ He3 and 2” X 2” NaI(Tl)

 

Berkeley SAM-935 w/ He3 and 3” X 3” NaI(Tl)

Canberra 35+, Exploranium GR-310,  GR-135 Identifier, LTI WIPER Wipe MCA w/ shielded well.

 

Alpha Spectroscopy (gas and solid state) Canberra 7401, DIAD, PIPS, Pylon WLx

Beta Spectroscopy (magnetic)

Neutron Detection He-3 probes from 1 inch to 56 inches, BTI Bubble Detector.  BC 704 paddles 5" X 26" X 3/8

Radon Quantification PYLON AB5, WLx, TEL, Lucas Cells, Thompson & Neilson Radon WL Meter & Printer, Ludlum Radon System (filter paper), PROIII long/short term digital.

5" Lucas cells w/ readers

 

Canberra 35+ 8196 channel MCA w/ Harshaw 3" x 3" well NaI (Tl), Canberra 2007 base

Canberra/NRC ADM-300 w/probes- alpha, beta, alpha/beta, X-Ray, Gamma, Calibration fixtures etc.

 

Ludlum 2218 dual SCA Analyzer, Ludlum 2" X 2" stabilized NaI (Tl) in Ludlum lead

Collimator or 2" X 2" NaI (Tl) in Picker Shielded Well

 

Ludlum 2929 with 43-10-1 sample counter

 

Ludlum 2500 SCA, Ludlum 2" x 2"  NaI (Tl) in Ludlum lead collimator

Ludlum 2600 SCA, Ludlum 2" x 2"  NaI (Tl) in Ludlum lead collimator

 

 

Scintrex GAD-6 w/ 3" X 3" NaI(Tl)

 

Ballard Liquid Scintillator

 

3 ea RM-20 (vehicular alarming ratemeters Gamma, beta, and Neutron)

 

Ludlum Model 500-2

MP-1 Pulser

MP-2 Pulser

Wm. B Johnson Varipulser

 

HAND HELD

LUDLUM

M- 2

M-3 4ea

M-3-98 INT: 2"Pancake GM, EXT: GM, Scint, Proportional

M-4

M-5                             Int GM, 2mR scale

M-9                 Low Range Ion-Chamber

 

M-12-98 INT 2" Pancake EXT: GM, Scint, Proportional

M-14C

 

M-2221 2ea.

M-2220 5 ea.

M-2223           A-B has A-B probe

M-2224 w/100 cm3 alpha-beta probe            M-L43-89

M-2300 Multifunctional Analyzer

M-2360 w/ 43-93 Gamma/Beta

 

 

 

 

 

BICRON:      

X-ray probe w/ preamp #1XMP.040B-X      2 ea.                           

Model Surveyor M. 1 has scaler and INT pancake

Analyzer with scaler option             

 

Radiographers (INT GM)                                                                            

RSO-5 Ion-Chamber

Micro-REM Tissue Equivalent                                                       

2-Micro-REM Tissue Equivalent *Low Energy version

2" X 2" Solid  NaI(Tl) with Canberra 2007P base

2" X 2"Well  NaI(Tl) with Canberra 2007P base

4" x 4" Gamma scint w. Canberra 2007P base

2" X 2" solid NaI (Tl) in 2" thick graded lead shield

 

 

 

LUDLUM PROBES 

43-1-1     Alpha-Beta dual Phosphor Scint -Large                             

43-1 Alpha Beta scint -Small

43-2 Alpha Scint         (cylinder)                                                                                                                   

43-10           #1Alpha Tray

43-10  #2Alpha Tray                                                                                                             

43-10-1 Alpha-Beta Tray

182 Flask Reader

218 Flask Reader

 

1" X 1" Gamma Scint 44-2  

44-3   LEG                             

44-6 GM Beta-Gamma Sidewall 6 ea.                        

SPA-6 2" X 2.4" Plastic Scint                       4 ea    

44-7 End-Window 6 ea.                                                         

44-9 Pancake 6 ea.                                                    

44-10 2" X 2" Gamma Scint

44-21 Beta/LEG Gamma scintillator 4 ea.                                                              

44-38 Energy Comp GM

44-133 high range GM probe

 

OTHER PROBES

Reuter Stokes 2" Xenon-Methane proportional X-Ray detectors, Be window

2 ea. T/A large Chrome Alpha scint

3" X 3" Gamma Scint

6 ea. LND GM End-Window/

3ea 2" NaI(Tl) in Thyroid Uptake shields

 

Gas Proportional test bench with Alpha, Beta  probes,  hemispherical probe.

 

EBERLINE PROBES                                                          

SPA-8 1" X 1" Gamma Scint           

AC-3   Alpha Scint    

HP-270 Energy Compensated Hand Probe

PG-2 2" Pu-239 LEG scints ( FIDLER)

HP-210 tungsten shielded pancake

 

 

 

 

OTHER INSTRUMENTS

 

Thermo PM1401GN Gamma/Neutron ratemeter w/He3

Thermo PM17101GN Gamma/Neutron ratemeter w/ He3

Fluke 451-P Pressurized Ion Chamber

Victoreen 440- RF/D

Femto Tech handheld Tritium in air monitor

Scintrex handheld Tritium in air monitor

Bench mount Tritium-C-14/Kr-85 monitor

Tracerco T201 Intrinsically Safe survey meter

Tracerco T202 Intrinsically Safe survey meter

AN/UDR-13

AN/PDQ-1

3 ea. Canberra ULTRARADIAC

Exploranium GR-135 IDENTIFIER handheldMCA/ dosimeter

GEOmetrics GR-310 portable MCA

Nuclear Enterprise w/ alpha, beta, 1" NaI (Tl)

SEI INSPECTOR    Digital pocket meter

SEI RAD-4

SEI Monitor-5

SEI MC1K energy compensated pocket model

ND-200 survey meter

RADOS 60 (Belt electronic dosimeter/ratemeter w alarm)

D-Tect Mini-Rad D alarming ratemeter

RAENeutron PM1703GN (belt scintillator ratemeter/alarm)

GM-45 USB

Aware RM-60

 

ANALYTICAL INSTRUMENTS

X-ray camera (video and still)

Crystal diffraction spectrometer

Keithly X-Ray kVp meter

Victoreen X-Ray exposure meter

Calibrated U ore set

Calibrated Ra-226 set

U Ore